Protection system against atmospheric discharges and electromagnetic protector that prevents lightning impact on the structure it protects.
The protection design is based on the installation of the DDCE 50 Plus in areas where waves can be coupled or in areas where interference can be generated.
In this case, the protection radius of the DDCE 50 plus may also be 50 m, as long as the regulatory requirements are met.
The DDCE 50 plus is recommended for installation in all types of ground structures.
Passive collector system for electrostatic currents in time, which diverts them to the ground, whose operating principle is based on balancing or compensating the variable electric field existing in its environment, preventing the generation of the ascending tracer in the DDCE Marine and in the marine vessel That protects.
DDCE Marine is recommended for all types of off-shore vessels.
Protection system against atmospheric discharges and electromagnetic protector that prevents lightning impact on the structure it protects.
Unique and effective system for protection from external electromagnetic pulses (absorbs PEM between 60 and 90%, minimizing damage due to indirect effects).
In this case, the protection radius of the DDCE 100 Plus may also be 100 m, as long as the regulatory requirements are met.
The DDCE 100 plus is recommended for installation in all types of ground structures.
Protection system against atmospheric discharges and electromagnetic protector that prevents lightning impact on the structure it protects
Unique and effective system for protection from external electromagnetic pulses (absorbs PEM between 60 and 90%, minimizing damage due to indirect effects).
In this case, the protection radius of the DDCE chemical may also be 100 m, as long as the regulatory requirements are met.
DDCE chemical is recommended in all types of installations in saline and corrosive environments.
Protection system against atmospheric discharges and electromagnetic protector that prevents lightning impact on the structure it protects
Unique and effective system for protection from external electromagnetic pulses (absorbs PEM between 60 and 90%, minimizing damage due to indirect effects).
In this case, the protection radius of the DDCE 100 plus UL may also be 100 m, as long as the regulatory requirements are met.
The DDCE 100 plus UL is recommended for installation in all types of ground structures.
The “dinfil” ground filter model DNNFT is a high reactance filter for protection against high frequency ground induced surges arising from atmospheric discharges, electromagnetic pulses and other sources.
Unique and effective system for the protection of ground-induced high-frequency surges in all types of structures.
The “dinfil” is recommended to be installed in all types of structures.
The DNNF model “dinco” connector is a protection element that minimizes induced high-frequency overvoltages derived from atmospheric discharges, electromagnetic pulses and other sources, which may appear on the DDCE downlink cable.
Its installation is recommended in all those structures whose exposure to this type of surges is not significant.
Passive Collector System of electrostatic currents on time, that takes them to the ground, whose operating principle is based on balancing or compensating the variable electric field on its surroundings, tending to avoid the creation of an upward leader on the DDCE and on to the protected structure.
Company
Newsletter
Subscribe to our newsletter and stay updated wit the latest news!